    We have been also specializing in improving the things administration and QC system to ensure that we could preserve terrific gain within the fiercely-competitive company for Natural Gas Monitoring System, ammonia gas detector, Carbon Dioxide Gas Detector, President of our company, with whole staff, welcomes all buyers to visit our company and inspect. Let us cooperate hand in hand to make a good future.
    Rapid Delivery for Lel On Gas Monitor - GT-AEC2338 Fixed Gas Detector – Action Detail:

    Technical Parameters

    Item

    Data

    Detected gases

    Combustible gases and steams, toxic and hazardous gases (see A01, A03 and B04~B29 in the list of detectable gases)

    Sampling mode

    Diffusive sampling

    Operating voltage

    DC24±6V

    Power consumption

    ≤3W (DC24V)

    Display

    LCD display

    Calibration

    By keys or a remote controller

    Signal transmission distance

    ≤1500m (2.5 mm2)

    Protection grade

    IP66

    Explosion proof grade

    ExdⅡCT6Gb

    Signal transmission

    Three-wire (4~20)mA standard signals [support HART] and 3 sets of relay signals

    Outlet hole connecting thread

    NPT3/4"(female)

    Material

    Cast aluminum

    Dimension

    Length × width × height: 228mm×177mm×87mm

    Weight

    1.9 kg

    Major Features

    Highly-integrated functional module design

    The integrated functional module is made up of two parts, i.e. detector module and sensor module. Anti-misplug standard digital interface is used between the two modules, good for on-site hot plug replacement;

    Alarm concentration can be set freely within the full range

    Low alarm concentration and high alarm concentration can be set freely within the full range. As keys are used for calibration, the calibrated value can be set according to calibrated gas concentration. Concentration is displayed through LCD on a real-time basis. On-site calibration can also be perfomed with an IR remote controller. At the time of calibration, it is unnecessary to open the cover. The operation is easy and convenient;

    Military-grade LCD display

    LCD real-time concentration display, clearly indicating equipment working conditions under highlight and in distance;

    Multiple communication modes are available

    Such product types as three-wire (4-20mA), two-wire (4-20mA), and 4-20mA with HART are available for selection;

    Flexible combination and multiple output modes

    Multiple detector modules and multiple types of sensor modules can be combined flexibly to form detectors with special output functions and applicable to different targets to meet customers’ customized demands;

    Replace a sensor as easy as replacing a bulb

    Sensor modules for different gases and ranges can be replaced freely. No calibration is required after replacement. That is, the detector can read ex-factory calibrated data and work immediately. In this way, the product has a longer service life. Meanwhile, detection calibration can be done easily at different sites, avoiding complicated dismantling process and difficult on-site calibration and reducing later maintenance cost.

    Model Selection

    Model

    Signal output

    Sensor equipped

    Adaptive control system

    AEC2338

    Three-wire (4~20)mA standard signal (supporting HART) and three sets of relay signals

    Two-wire (4~20)mA standard signal (supporting HART)

    Catalytic combustion, semiconductor, electrochemical, IR & PID

    ACTION gas alarm controllers:

    AEC2392a, AEC2392b, AEC2393a , AEC2393b2a-BS, AEC2393b2a-BM

    Detector Structure

    Boundary Dimension

    Material cast aluminum; Dimension: Length× width× height: 228mm×177mm×87mm Weight: 1.9 kg

    Mounting Mode

    Vertical pipe-mounted / Horizontal pipe-mounted / Wall-mounted / Ceiling-mounted


    Product detail pictures:

    Rapid Delivery for Lel On Gas Monitor - GT-AEC2338 Fixed Gas Detector – Action detail pictures

    Rapid Delivery for Lel On Gas Monitor - GT-AEC2338 Fixed Gas Detector – Action detail pictures

    Rapid Delivery for Lel On Gas Monitor - GT-AEC2338 Fixed Gas Detector – Action detail pictures


    Related Product Guide:

    With our rich working experience and thoughtful companies, we have now been recognized as being a trustworthy supplier for a lot of global potential buyers for Rapid Delivery for Lel On Gas Monitor - GT-AEC2338 Fixed Gas Detector – Action , The product will supply to all over the world, such as: Finland, Costa Rica, Madras, If you are for any reason unsure which product to select, do not hesitate to contact us and we will be delighted to advise and assist you. This way we will be providing you with all the knowledge needed to make the best choice. Our company strictly follows "Survive by good quality, Develop by keeping good credit. " operation policy. Welcome all the clients old and new to visit our company and talk about the business. We are looking for more and more customers to create the glorious future.
  • We feel easy to cooperate with this company, the supplier is very responsible, thanks.There will be more in-depth cooperation.
    5 Stars By Elva from Panama - 2017.03.28 12:22
    The goods we received and the sample sales staff display to us have the same quality, it is really a creditable manufacturer.
    5 Stars By Anna from Seychelles - 2017.11.01 17:04
    Write your message here and send it to us