  • This series of detectors adopts integrated functional module design, which is convenient for on-site hot swapping and replacement. It can be equipped with various types of sensors, such as catalytic sensor, semiconductor sensor, electrochemical sensor, infrared (IR) sensor, photoion (PID) sensor, etc. and can detect various toxic and combustible gas concentrations (ppm /% LEL /% VOL) on site. The detector has the characteristics of flexible combination, quick and easy replacement, stable performance, good consistency, high sensitivity, low power consumption, multiple outputs and optional detection methods. It is widely used in petroleum, chemical industry, pharmacy, steel, special industrial plants and other places with combustible or toxic and harmful gases.

    Welcome to click the Inquiry button to obtain the free samples!

    ACTION gas detectors are OEM & ODM supported and true mature devices, long-tested in millions of projects domestic and overseas since 1998! Don't hesitant to leave your any inquiry here!


    Product Detail

    Product Tags

    We can normally fulfill our respected consumers with our great excellent, great value and good provider due to we’re much more specialist and extra hard-working and do it in cost-effective way for 100% Original Factory Fixed Combustible Gas Leakage Detector Industrial Natural Gas Detector, We have now much more than 20 years experience with this industry, and our profits are perfectly experienced. We can easily supply you with the most specialist solutions to meet your products’ needs. Any troubles, appear to us!
    We can normally fulfill our respected consumers with our great excellent, great value and good provider due to we’re much more specialist and extra hard-working and do it in cost-effective way for China Gas Detector and Natural Gas Detector, Immediate and expert after-sale service supplied by our consultant group has happy our buyers. Comprehensive Info and parameters from the merchandise will probably be sent to you for any comprehensive acknowledge. Free samples may be delivered and company check out to our corporation. n Morocco for negotiation is constantly welcome. Hope to get inquiries type you and construct a long-term co-operation partnership.

    Product Selling Point

    1) 4 ~ 20mA standard signal, supporting HART protocol

    Lightweight design, three wire system (4 ~ 20) mA standard signal, using first-line brand imported sensor, supporting HART protocol

    2) Highly-integrated functional module design

    The sensor module integrates a sensor and a processing circuit, to complete all data operation and signal switching of the detector independently. Its unique heating function expands the detector’s low temperature service capability. The detector module is for power supply, communication and output functions;

    3) Overlimit protection for high concentration

    In case of overlimit of high concentration gas, the sensor module can cut off power supply automatically. Detection works every 30s until the concentration is normal and power supply is resumed. This function can prevent reduction of the sensor’s service life resulted from being submerged in high concentration gas;

    4) Standardized digital interface

    Standard digital interfaces are used between modules. Anti-misplug gold-plated pins are good for on-site hot plug replacement;

    5) Flexible combination and multiple output modes

    Multiple detector modules and multiple types of sensor modules can be combined flexibly to form detectors with special output functions and applicable to different targets to meet customers’ customized demands;

    6) Replace a sensor as easy as replacing a bulb

    Sensor modules for different gases and ranges can be replaced freely. No calibration is required after replacement. That is, the detector can read ex-factory calibrated data and work immediately. In this way, the product has a longer service life. Meanwhile, detection calibration can be done easily at different sites, avoiding complicated dismantling process and difficult on-site calibration and reducing later maintenance cost;

    7) On-site LED concentration display, and diversified calibration modes

    Highlight LED real-time concentration display, with farther and wider visual distance and angle, applicable to industrial environment requirements; the detector can be set/calibrated in different ways, such as by keys or by an IR remote controller or a magnetic bar, and it is easy to operate;

    8) Explosion-proof design

    Enclosure of this product is made of cast aluminum or stainless steel materials and its explosion proof grade reaches Exd II CT6 Gb.

    Product Parameter Characteristics

    Optional sensor

    Catalytic combustion, Semiconductor, Electrochemical, Infrared ray(IR), Photoion(PID)

    Sampling mode

    Diffusive sampling

    Operating voltage

    DC24V±6V

    Alarm error

    Combustible gases

    ±3%LEL

    Indication error

    Combustible gases

    ±3%LEL

     

    toxic and hazardous gases

    Alarm setting value ±15%, O2:±1.0%VOL

     

    toxic and hazardous gases

    ±3%FS ( toxic and hazardous gases), ±2%FS (O2)

    Power consumption

    3W(DC24V)

    Signal transmission distance

    ≤1500m(2.5mm²)

    Press range

    86kPa~106kPa

    Humidity range

    ≤93%RH

    Explosion proof grade

    ExdⅡCT6

    Protection grade

    IP66

    Electrical interface

    NPT3/4" internal thread

    Shell material

    cast aluminum or stainless steel

    Operating temperature

    Catalytic combustion, Semiconductor, Infrared ray(IR): -40℃~+70℃; Electrochemical:  -40℃~+50℃; Photoion(PID):-40℃~+60℃

    Optional signal transmission mode

    1) A-BUS+ four-bus system signal and contact outputs of two sets of relays

    2) Three-wire (4~20)mA standard signals and contact outputs of three sets of relays

    Note:

    (4~20) mA standard signal is {maximum load resistance: <250Ω(18VDC~20VDC), <500Ω(20VDC~30VDC)}

    The relay signal is {alarm relay passive normally open contact output; fault relay passive normally closed contact output (contact capacity: DC24V /1A)}

    Alarm concentration

    The factory alarm setting value is different due to different sensors, the alarm concentration can be set arbitrarily in the full range, please consult




    We can normally fulfill our respected consumers with our great excellent, great value and good provider due to we’re much more specialist and extra hard-working and do it in cost-effective way for 100% Original Factory Fixed Combustible Gas Leakage Detector Industrial Natural Gas Detector, We have now much more than 20 years experience with this industry, and our profits are perfectly experienced. We can easily supply you with the most specialist solutions to meet your products’ needs. Any troubles, appear to us!
    100% Original Factory China Gas Detector and Natural Gas Detector, Immediate and expert after-sale service supplied by our consultant group has happy our buyers. Comprehensive Info and parameters from the merchandise will probably be sent to you for any comprehensive acknowledge. Free samples may be delivered and company check out to our corporation. n Morocco for negotiation is constantly welcome. Hope to get inquiries type you and construct a long-term co-operation partnership.