Innovation, quality and reliability are the core values of our company. These principles today more than ever form the basis of our success as an internationally active mid-size company for Ammonia Air Detector, Refrigerant Gas Leak Detector Fixed, Leak Detector For Gas, To provide customers with excellent equipment and services, and constantly develop new machine is our company's business objectives. We look forward to your cooperation.
Toxic Gas Analyzer GT-AEC2331a Industrial and commercial combustible gas detector – Action Detail:
Technical Parameters
|
Item
|
Data
|
|
Detected gases
|
Natural gas
|
|
Principle of detection
|
Catalytic combustion
|
|
Sampling mode
|
Diffusive sampling
|
|
Range
|
3-100%LEL
|
|
Operating voltage
|
DC24±6V
|
|
Power consumption
|
≤1W (DC24V)
|
|
Electrical interface
|
NPT3/4"
|
|
Protection grade
|
IP66
|
|
Explosion proof grade
|
ExdⅡCT6Gb
|
|
Shell
|
Cast aluminum
|
|
Dimension
|
Length × width × thickness: 110mm×103mm×55mm
|
|
Weight
|
About 530g
|
Major Features
High intelligence and digitalization
High-performance micro-controller technology, automatic failure identification and automatic alarm, high-concentration gas over limit protection;
Only one ESN. No code dialing is required, reducing the complexity of manual code dialing;
Sensitivity curve attenuation compensation
Advanced embedded software treatment technology, automatic service life attenuation compensation and high sensitivity;
Real-time concentration detection
Real-time gas concentration detection; concentration information is transmitted to an adaptive controller;
Portable and small size, easy to mount
The product is portable and small in size, applicable to diversified mounting modes and easy to mount.
Model Selection
|
Model
|
Signal output
|
Sensor equipped
|
Adaptive control system
|
|
GT- AEC2331a
|
Four-bus communication
(S1, S2, GND and +24V)
|
Catalytic combustion
|
ACTION gas alarm controllers:
AEC2301a, AEC2302a, AEC2303a and AEC2305
|
Detector Structure
1. Install bottom board
2. Bottom box
3. Explosion-proof single-sealed cable gland
4. M4 x10 Hexagon socket head cap screw
5. Sensor cover
6. Light guide
7. Top cover

Detector Structure

A. Holding pipe-mounted (Holding pipe diameter DN20)

B. Vertical pipe-mounted (Holding pipe diameter DN20)

C. Wall-mounted

D. Ceiling-mounted
Product detail pictures:
Related Product Guide:
Our business puts emphasis on the administration, the introduction of talented personnel, as well as the construction of team building, trying hard to further improve the standard and liability consciousness of staff members customers. Our enterprise successfully attained IS9001 Certification and European CE Certification of Toxic Gas Analyzer GT-AEC2331a Industrial and commercial combustible gas detector – Action , The product will supply to all over the world, such as: Angola, Washington, Manchester, Our company will adhere to "Quality first, , perfection forever, people-oriented , technology innovation"business philosophy. Hard work to keep making progress, innovation in the industry, make every effort to first-class enterprise. We try our best to build the scientific management model, to learn abundant professional knowledge, to develop advanced production equipment and production process , to create the first-call quality products, reasonable price , high quality of service , quick delivery , to give you create new value .