  • ACTION gas detectors are OEM & ODM supported and true mature devices, long-tested in millions of projects domestic and overseas since 1998! Don't hesitant to leave your any inquiry here!


    Product Detail

    Product Tags

    Related Video

    Feedback (2)

    With our leading technology as well as our spirit of innovation,mutual cooperation, benefits and development, we will build a prosperous future together with your esteemed company for Gas Co Detector, gas detecting control panel, Four Gas Monitors, We welcome customers, business associations and friends from all parts of the world to contact us and seek cooperation for mutual benefits.
    Phosphine Ph3 Gas Detector GT-AEC2338 Fixed Gas Detector – Action Detail:

    Technical Parameters

    Item

    Data

    Detected gases

    Combustible gases and steams, toxic and hazardous gases (see A01, A03 and B04~B29 in the list of detectable gases)

    Sampling mode

    Diffusive sampling

    Operating voltage

    DC24±6V

    Power consumption

    ≤3W (DC24V)

    Display

    LCD display

    Calibration

    By keys or a remote controller

    Signal transmission distance

    ≤1500m (2.5 mm2)

    Protection grade

    IP66

    Explosion proof grade

    ExdⅡCT6Gb

    Signal transmission

    Three-wire (4~20)mA standard signals [support HART] and 3 sets of relay signals

    Outlet hole connecting thread

    NPT3/4"(female)

    Material

    Cast aluminum

    Dimension

    Length × width × height: 228mm×177mm×87mm

    Weight

    1.9 kg

    Major Features

    Highly-integrated functional module design

    The integrated functional module is made up of two parts, i.e. detector module and sensor module. Anti-misplug standard digital interface is used between the two modules, good for on-site hot plug replacement;

    Alarm concentration can be set freely within the full range

    Low alarm concentration and high alarm concentration can be set freely within the full range. As keys are used for calibration, the calibrated value can be set according to calibrated gas concentration. Concentration is displayed through LCD on a real-time basis. On-site calibration can also be perfomed with an IR remote controller. At the time of calibration, it is unnecessary to open the cover. The operation is easy and convenient;

    Military-grade LCD display

    LCD real-time concentration display, clearly indicating equipment working conditions under highlight and in distance;

    Multiple communication modes are available

    Such product types as three-wire (4-20mA), two-wire (4-20mA), and 4-20mA with HART are available for selection;

    Flexible combination and multiple output modes

    Multiple detector modules and multiple types of sensor modules can be combined flexibly to form detectors with special output functions and applicable to different targets to meet customers’ customized demands;

    Replace a sensor as easy as replacing a bulb

    Sensor modules for different gases and ranges can be replaced freely. No calibration is required after replacement. That is, the detector can read ex-factory calibrated data and work immediately. In this way, the product has a longer service life. Meanwhile, detection calibration can be done easily at different sites, avoiding complicated dismantling process and difficult on-site calibration and reducing later maintenance cost.

    Model Selection

    Model

    Signal output

    Sensor equipped

    Adaptive control system

    AEC2338

    Three-wire (4~20)mA standard signal (supporting HART) and three sets of relay signals

    Two-wire (4~20)mA standard signal (supporting HART)

    Catalytic combustion, semiconductor, electrochemical, IR & PID

    ACTION gas alarm controllers:

    AEC2392a, AEC2392b, AEC2393a , AEC2393b2a-BS, AEC2393b2a-BM

    Detector Structure

    Boundary Dimension

    Material cast aluminum; Dimension: Length× width× height: 228mm×177mm×87mm Weight: 1.9 kg

    Mounting Mode

    Vertical pipe-mounted / Horizontal pipe-mounted / Wall-mounted / Ceiling-mounted


    Product detail pictures:

    Phosphine Ph3 Gas Detector GT-AEC2338 Fixed Gas Detector – Action detail pictures

    Phosphine Ph3 Gas Detector GT-AEC2338 Fixed Gas Detector – Action detail pictures

    Phosphine Ph3 Gas Detector GT-AEC2338 Fixed Gas Detector – Action detail pictures


    Related Product Guide:

    We have now sophisticated machines. Our solutions are exported to the USA, the UK and so on, enjoying a great reputation amid consumers for Phosphine Ph3 Gas Detector GT-AEC2338 Fixed Gas Detector – Action , The product will supply to all over the world, such as: Namibia, Slovakia, Ethiopia, For many years, we have adhered to the principle of customer oriented, quality based, excellence pursuing, mutual benefit sharing. We hope, with great sincerity and good will, to have the honor to help with your further market.
    Staff is skilled, well-equipped, process is specification, products meet the requirements and delivery is guaranteed, a best partner!
    5 Stars By John biddlestone from French - 2018.06.28 19:27
    The company leader recept us warmly, through a meticulous and thorough discussion, we signed a purchase order. Hope to cooperate smoothly
    5 Stars By Jacqueline from Bulgaria - 2018.06.21 17:11
    Write your message here and send it to us