banenr

product

OEM Factory for Gas Leak Monitoring System - GT-AEC2232a Series Fixed Gas Detector – Action

Short Description:

  • logo1
  • logo2
  • logo3
  • logo4
  • logo5
  • logo6
  • logo7
  • logo8
  • logo9
  • logo10
  • logo11
  • logo12
  • logo13
  • logo14
  • ACTION gas detectors are OEM & ODM supported and true mature devices, long-tested in millions of projects domestic and overseas since 1998! Don't hesitant to leave your any inquiry here!


    Product Detail

    Product Tags

    Related Video

    Feedback (2)

    The incredibly rich projects administration experiences and a person to 1 service model make the substantial importance of organization communication and our easy understanding of your expectations for Carbon Monoxide Alarm Detector, Cooking Gas Leak Detector, Gas Detector Confined Space, Sincerely hope to build long term business relationships with you and we will do our best service for you.
    OEM Factory for Gas Leak Monitoring System - GT-AEC2232a Series Fixed Gas Detector – Action Detail:

    Product Selling Point

    1) Beautiful and compact design

    Small design, Small size, more space saving;

    2) Modular design

    The sensor can be hot-swapped and replaced, reducing the follow-up maintenance cost of the product. Especially for electrochemical sensors with a short life, it can save users a lot of replacement costs;

    3) Can be equipped with explosion-proof audible and visual alarm

    It can be equipped with ACTION explosion-proof audible and visual alarm to meet the needs of users for audible and visual (especially for the detection of toxic gases);

    4) High reliability digital tube display

    With digital tube concentration display and status indication function, gas concentration and equipment operating status can be observed on site;

    5) Selection of commonly used toxic and combustible gases

    Solve the detection needs of most gas and small and medium-sized plants (CH4, C3H8 (propane), Co, H2S, NH3, SO2, O2, H2);

    6) Fast response time and high sensitivity

    7) With dust explosion-proof certification, expand the application scope of small and medium-sized plants

    Product Parameter Characteristics

    Detection principle Catalytic combustion, Electrochemical Signal transmission mode A-BUS+、4-20mA、RS485
    Sampling mode Diffusive sampling Alarm error ±3%LEL
    Operating voltage DC24V±6V Indication error ±3%LEL(display on the connected gas alarm controller)
    Display mode Digital tube display Sound and light configuration Optional ACTION explosion-proof audible and visual alarm
    Power consumption <3W(DC24V) Signal transmission distance ≤1500m(2.5mm2 )
    Press range 86kPa~106kPa Operating temperature -40℃~+70℃
    Explosion proof grade Catalytic combustion:ExdⅡCT6Gb/Ex tD A21 IP66 T85℃ (Explosion-proof + dust)Electrochemical:Ex d ib ⅡC T6 Gb/Ex t D ibD A21 IP66 T85℃(Explosion-proof + dust) Humidity range ≤93%RH
    Shell material Cast aluminum Protection grade IP66
    Electrical interface NPT3/4"internal thread

    Ordering Selection Table

    Model

    Signal output

    Matching sensor

    Adaptive control system

    GT-AEC2232a

    Four bus communication(S1,S2,GND,+24V)

    Catalytic combustion or Electrochemical

    ACTION gas alarm controller: AEC2301a, AEC2302a, AEC2303a

    GT-AEC2232aT

    Three-wire 4~20mA

    Catalytic combustion or Electrochemical

    ACTION gas alarm controller: AEC2392a, AEC2392b, AEC2393a, AEC2392a-BS, AEC2392a-BM

    GT-AEC2232aM

    RS485 signal

    Catalytic combustion or Electrochemical

    RS485 A-BUS+ system




    Product detail pictures:

    OEM Factory for Gas Leak Monitoring System - GT-AEC2232a Series Fixed Gas Detector – Action detail pictures

    OEM Factory for Gas Leak Monitoring System - GT-AEC2232a Series Fixed Gas Detector – Action detail pictures


    Related Product Guide:

    Our corporation insists all along the quality policy of "product top quality is base of organization survival; purchaser pleasure will be the staring point and ending of an company; persistent improvement is eternal pursuit of staff" plus the consistent purpose of "reputation very first, purchaser first" for OEM Factory for Gas Leak Monitoring System - GT-AEC2232a Series Fixed Gas Detector – Action , The product will supply to all over the world, such as: Los Angeles, Canberra, Canada, Our products are widely recognized and trusted by users and can meet continuously developing economic and social needs. We welcome new and old customers from all walks of life to contact us for future business relationships and achieving mutual success!
  • Wide range, good quality, reasonable prices and good service, advanced equipment, excellent talents and continuously strengthened technology forces,a nice business partner.
    5 Stars By Michaelia from panama - 2017.09.26 12:12
    Cooperate with you every time is very successful, very happy. Hope that we can have more cooperation!
    5 Stars By Jill from Mauritius - 2018.02.08 16:45
    Write your message here and send it to us