    Product Detail

    Product Tags

    Related Video

    Feedback (2)

    Well-run equipment, expert income workforce, and far better after-sales expert services; We are also a unified large family, anyone stick to the corporate value "unification, dedication, tolerance" for natural gas solenoid valve, Gas Detection Control, gas leakage detector, Our Enterprise Core Principle: The prestige 1st ;The quality guarantee ;The customer are supreme.
    Good Quality Gas Detection Panel - AEC2302a Gas Detection Controller System – Action Detail:

    Technical Specifications

    Operating voltage  AC176V~AC264V (50Hz±1%)
    Power consumption  ≤10W (excluding supporting equipment)
    Environmental condition for operating  temperature-10℃~+50℃, relative humidity≤93%RH
    Signal transmission  four-bus system (S1, S2, +24V and GND)
    Signal transmission distance  1500m (2.5mm2)
    Types of gas detected  %LEL, ppm and %VOL
    Capacity  total number of detectors and input modules≤16
    Number of expandable output modules  ≤16
    Adaptive equipment(gas detectors)  GT-AEC2331a, GT-AEC2232a,GT-AEC2232bX/A,GQ-AEC2232bX/A
    Input module  JB-MK-AEC2241 (d)
    Output module  JB-MK-AEC2242 (d)
    Fan linkage boxes  JB-ZX-AEC2252F and JB-ZX-AEC2252F/M
    Solenoid valve linkage boxes JB-ZX-AEC2252B and JB-ZX-AEC2252B/M
    Output  four sets of relay contact signals, with the capacity of 3A/DC24V or 1A/AC220V RS485 bus communication interface (standard MODBUS protocol)
    Alarm setting  low alarm and high alarm
    Alarming mode  audible-visual alarm
    Display mode  nixie tube
    Boundary dimensions (length ×width ×thickness) 420mm×320mm×120mm
    Mounting mode  wall-mounted
    Standby power supply  DC12V /4Ah ×2

    Major Features

    ● Bus signal transmission, strong system anti-interference capability, cost-efficient wiring, convenient and efficient installation;

    ● Real-time gas concentration (%LEL/ppm/%VOL) monitoring interface or time display interface for user’s choice;

    ● Free setting of two level alarm values and three alarming types (rising/falling/two-level);

    ● Calibrate and trace the sensor aging automatically;

    ● Fault automatic monitoring; indicate the fault location and type correctly;

    ● Strong logic programming and free configurations of output modules can realized remote automatic control over various kinds of external equipment; four programmable emergency buttons can manually output control signals;

    ● Strong memory: historical records of the latest 999 alarming records, 100 failure records and 100 startup/shutdown records, which will not be lost in case of power failure;

    ● RS485 bus communication (standard MODBUS protocol) interface to realize communication with the host control system and networking with the fire and gas network system, to improve system integration.

    Structure

    1. Side lock
    2. Cover
    3. Horn
    4. Bottom box
    5. Bus connection terminal
    6. RS485 bus communication interface
    7. Relay connection terminal
    8. Incoming hole
    9. Power supply terminal
    10. Grounding terminal
    11. Switch of main power supply
    12. Switch of standby power supply
    13. Switch power supply
    14. Standby power supply
    15. Control panel

    Panel Marks And Mounting Instructions


    ● Make 4 mounting holes (hole depth: ≥40mm) in a wall as per the requirements for bottom board mounting holes (hole symbols 1-4);

    ● Insert a plastic expansion bolt into each mounting hole;

    ● Fix the bottom board onto the wall, and fasten it onto the expansion bolts with 4 self-tapping screws (ST3.5×32);

    ● Hang the welding hanging parts on the back of the controller onto location A at the bottom board to complete mounting of the controller.

    Wiring Diagram

    N, and L: AC220V power supply terminals

    NO (normally open), COM (common) and NC (normally closed): (4 sets) output terminals for relay external control signals output terminals

    S1, S2, GND and +24V: (4 sets) bus connection terminals (≤64 points for each set)

    A, GND and B: RS485 communication interface connection terminals


    Product detail pictures:

    Good Quality Gas Detection Panel - AEC2302a Gas Detection Controller System – Action detail pictures

    Good Quality Gas Detection Panel - AEC2302a Gas Detection Controller System – Action detail pictures


    Related Product Guide:

    We are also specializing in improving the things management and QC method in order that we could retain terrific edge inside the fiercely-competitive small business for Good Quality Gas Detection Panel - AEC2302a Gas Detection Controller System – Action , The product will supply to all over the world, such as: Canberra, Peru, Eindhoven, We have advanced production technology, and pursuit innovative in goods. At the same time, the good service has enhanced the good reputation. We believe that as long as you understand our product, you need to be willing to become partners with us. Looking forward to your inquiry.
  • Customer service staff and sales man are very patience and they all good at English, product's arrival is also very timely, a good supplier.
    5 Stars By Barbara from Swansea - 2017.05.31 13:26
    We always believe that the details decides the company's product quality, in this respect, the company conform our requirements and the goods are meet our expectations.
    5 Stars By Dee Lopez from Norwegian - 2017.10.25 15:53
    Write your message here and send it to us