    The very rich projects management experiences and one to one service model make the high importance of business communication and our easy understanding of your expectations for lpg wifi detector, Gas Detection Tube, Gas Detection Control, Through more than 8 years of business, we have accumulated rich experience and advanced technologies in the production of our products.
    Gas Control Panel AEC2392a-BS/BM Gas Controller – Action Detail:

    Technical Specifications

    Item  

    Data

    Configuration

    One master control card, seven channel cards and one wall-mounted casing(AEC2392a-BS)

    One master control card, fifteen channel cards and one wall-mounted casing(AEC2392a-BM)

    Boundary dimension of the rack

    Wall-mounted casing (length × width x height: 426mm×392mm×117mm) (AEC2392a-BS)

    Wall-mounted casing (length × width x height: 430mm×565mm×145mm) (AEC2392a-BM)

    Item

    Master control card

    Channel card

    Operating power supply

    DC24V±6V

    Types of gas detected

    %LEL/%VOL/ppm

    Range

    (0~100)%LEL, (0~100)%VOL, (0~9999)ppm

    Value indication error

    ±5%FS

    Operating mode

    Connected to channel cards or working independently

    Connected to the master control card or working independently

    Capacity

    8(16), to connect seven channel cards; the master control card can connect one set of 4-20mA standard current signal

    One channel card connects one 4-20mA transmitter

    Power consumption

    3W

    1W/channel card

    Input signals

    Connect to (4~20)mA standard current signals or passive switching value signals locally or via a channel card

    4~20mA standard current signals or passive switching value signals

    Output signals

    1. RS485 bus communication signal (standard MODBUS protocol);2. Signals of 3 sets of relays (relays 1, 2 and 3); contact capacity: AC250V/10A or DC30V/10A. One channel card can output:Signals of 3 sets of relays (high alarm, low alarm and failure); contact capacity: AC250V/10A or DC30V/10A

    Environmental condition for operating

    Temperature: 0℃~+40℃; relative humidity: ≤93%; atmospheric pressure: 86kPa~106kPa

    Alarming mode

    Audible alarm and LED visual alarm

    LED visual alarm

    Display mode

    OLCD Chinese display

    LCD segment code display

    Switch power supply

    AC176V~AC264V (50Hz±0.5Hz); under voltage test point 170V±10V; main power supply’s max. working current: 1A

    External standby power supply

    DC12V /4Ah×2 lead-acid battery (AEC2392a-BS)

    DC12V /7Ah×2 lead-acid battery (AEC2392a-BM)

    Mounting mode

    Wall-mounted

    Note: The default system input signals are (4~20)mA standard signals; when the input signal is a passive switching value signal, the default signal is a passive normally-open signal; if a user requires that the default signal should be a passive normally-close signal under such case, please specify when ordering.

    Major Features

    ● Three-wire system signal transmission; wall-mounted casing; anti-RFI/EMI interference;

    ● This product has a beautiful appearance and a portable size, several devices can be wall-mounted together;

    ● The master control card and channel cards are set separately but have a function of synchronous display. With a large LCD Chinese display screen, the master control card can realize Chinese menu operation as well as faster and easier display and operation;

    ● The master control card and channel cards are set separately but have a function of synchronous display. With a large LCD Chinese display screen, the master control card can realize Chinese menu operation as well as faster and easier display and operation;

    ● Channel cards’ multiple output types are applicable to linkage of on-site external control devices. By using standard MODBUS communication protocol, RS485 communication function can communicate with the host computer (e.g. DCS/PLC/EDS/RTU, etc.);

    ● Channel cards can receive 4-20mA signal or switching value signal input and be connected with various devices, including combustible gas detectors, toxic and hazardous gas detectors, oxygen detectors, flame detectors, smoke/heat detectors and manual alarming buttons, etc;

    ● Save the latest 999 alarming records, 999 failure records and 100 startup/shutdown records for check, which will not be lost in case of power failure;

    ● Channel cards have a three-color backlight LCD, which can indicate normal, failure and alarming status clearly;

    ● The master control card integrates the functions of the power supply card and the one-circuit channel card. All channels can be equipped with a HART communication module, showing a strong function.

    Control panel

    The control panel contains the display interfaces and operating interfaces of the master control card and channel cards, including the display screen, the LED status indicator, the alarm buzzer (installed inside the master control card) and operating keys. The master control card has ten operating keys while a channel card has three ones (see the following diagram):

    Mounting


    ● Make 4 or 6 mounting holes (hole depth: ≥40mm) in a wall according to the requirements for the size among mounting holes (hole symbols 1 – 6) for mounting the hanging plate;

    ● Insert a plastic expansion bolt into each mounting hole;

    ● Fix the hanging plate onto the wall and fasten it onto the expansion bolts with 4 or 6 self-tapping screws (ST4.2×25);

    ● Hang the hanging parts at the bottom of the controller onto location A at the bottom board to complete mounting of the controller.

    External interface

    The master control card connects 9 circuits of channel cards. Each channel card collects 4-20mA multi-line or passive switching value signal output communication equipment, such as GT-AEC2232bX, GQ-AEC2232bX, GT-AEC2232aT, AEC2338, GQ-AEC2232bX-P, AEC2338-D detectors and flame detectors. It can also connect other 4-20mA output transmitters. Two sets of built-in modules of the master control card can realize remote linkage of external devices (on-site sound and light, solenoid valves and fans, etc.). External devices (e.g. on-site sound and light) can also be controlled through three sets of relay signal output terminals provided by each channel card. Remote communication with the host system can be done through the RS485 communication interface so that the host system can monitor AEC2392a-BS/AEC2392a-BM gas detection systems in several areas intensively.

    Master control card:

    485A and 485B: RS485 communication interface connection terminals

    L, PG and N: AC220V power supply terminals

    NC*(normally closed), COM* (common) and NO* (normally open): (3 sets) output terminals for relay external control signals output terminals

    V+, SIN and GND:  input terminals for 4~20mA or passive switching value signals

    Channel card:

    NC*(normally closed), COM* (common) and NO* (normally open): (3 sets) output terminals for relay external control signals output terminals

    24V, SIN and GND: input terminals for 4~20mA or passive switching value signals

    When the signal connected is a passive switching value signal, the two ends of the signal are connected to 4~20mA (IN) and +24V. If DC24V power will be supplied to the equipment connected, the wiring is as shown in the system configuration diagram.

    Internal terminal:

    CAH, CAL, VSS and 24V: connection terminals for internal communication (connected in the factory)

    Notes: (1) The maximum allowable wire diameter for connection terminals is 2.5mm2. (2)Factory default of the master control card’s relay output is passive switching value signal.


    Product detail pictures:

    Gas Control Panel AEC2392a-BS/BM Gas Controller – Action detail pictures

    Gas Control Panel AEC2392a-BS/BM Gas Controller – Action detail pictures

    Gas Control Panel AEC2392a-BS/BM Gas Controller – Action detail pictures

    Gas Control Panel AEC2392a-BS/BM Gas Controller – Action detail pictures


    Related Product Guide:

    We know that we only thrive if we can guarantee our combined rate competiveness and good quality advantageous at the same time for Gas Control Panel AEC2392a-BS/BM Gas Controller – Action , The product will supply to all over the world, such as: Bhutan, Argentina, Indonesia, Our products are very popular in the word, like South American, Africa, Asia and so on. Companies to "create first-class products" as the goal, and strive to provide customers with high quality products, provide high-quality after-sales service and technical support, and customer mutual benefit, create a better career and future!
    In China, we have many partners, this company is the most satisfying to us, reliable quality and good credit, it is worth appreciation.
    5 Stars By Hilda from Sierra Leone - 2018.09.12 17:18
    The quality of the products is very good, especially in the details, can be seen that the company work actively to satisfy customer's interest, a nice supplier.
    5 Stars By Elizabeth from Georgia - 2017.09.26 12:12
    Write your message here and send it to us