    Our organization promises all customers with the first-class products and solutions and the most satisfying post-sale service. We warmly welcome our regular and new clients to join us for Lpg Detector Gas, Carbon Monoxide And Gas Detector, Gas Detection Companies, Our merchandise are widely recognized and dependable by users and can meet continuously building economic and social needs.
    Combustible Gas Detection Controller Gas Alarm Controller AEC2303a – Action Detail:

    Technical Specifications

    Operating voltage  AC176V~AC264V (50Hz±1%)
    Power consumption  ≤10W (excluding supporting equipment)
    Environmental condition for operating  temperature-10℃~+50℃, relative humidity≤93%RH
    Signal transmission  four-bus system (S1, S2, +24V and GND)
    Signal transmission distance  1500m (2.5mm2)
    Types of gas detected  %LEL
    Capacity  total number of detectors and input modules≤4
    Adaptive equipment  gas detectors GT-AEC2331a, GT-AEC2232a, GT-AEC2232bX/A
    Input module  JB-MK-AEC2241 (d)
    Fan linkage boxes  JB-ZX-AEC2252F
    Solenoid valve linkage boxes JB-ZX-AEC2252B
    Output  two sets of relay contact signals, with the capacity of3A/DC24V or 1A/AC220V RS485Bus communication interface (standard MODBUS protocol)
    Alarm setting  low alarm and high alarm
    Alarming mode  audible-visual alarm
    Display mode  nixie tube
    Boundary dimensions(length ×width ×thickness)  320mm×240mm×90mm
    Mounting mode  wall-mounted
    Standby power supply  DC12V /1.3Ah ×2

    Major Features

    ● Bus signal transmission, strong system anti-interference capability, cost-efficient wiring, convenient and efficient installation;

    ● Real-time gas concentration (%LEL) monitoring interface or time display interface for user’s choice;

    ● One-button start for simple and convenient system commissioning;

    ● Freely setting the alarm values of the two alarming levels in the full-scale range;

    ● Automatic calibration, and automatic tracing of sensor ageing;

    ● Automatically monitoring failure; correctly showing the failure location and type;

    ● Two sets of programmable internal linkage output modules and two programmable emergency buttons to automatically or manually control external equipment;

    ● Strong memory: historical records of the latest 999 alarming records, 100 failure records and 100 startup/shutdown records, which will not be lost in case of power failure;

    ● RS485 bus communication (standard MODBUS protocol) interface to realize communication with the host control system and networking with the fire and gas network system, to improve system integration.

    Structure

    1. Side lock
    2. Cover
    3. Horn
    4. Bus connection terminal
    5. RS485 bus communication interface
    6. Relay connection terminal
    7. Bottom box
    8. Incoming hole
    9. Grounding terminal
    10. Power supply terminal
    11. Switch of main power supply
    12. Switch of standby power supply
    13. Switch power supply
    14. Standby power supply
    15. Control panel

    Panel Marks And Mounting Instructions


    ● Make 4 mounting holes (hole depth: ≥40mm) in a wall as per the requirements for bottom board mounting holes (hole symbols 1-4);

    ● Insert a plastic expansion bolt into each mounting hole;

    ● Fix the bottom board onto the wall, and fasten it onto the expansion bolts with 4 self-tapping screws (ST3.5×32);

    ● Hang the welding hanging parts on the back of the controller onto location A at the bottom board to complete mounting of the controller.

    Panel Marks And Mounting Instructions

    L,and N: AC220V power supply terminals

    NC (normally closed), COM (Common) and NO (normally open): (2 sets) output terminals for relay external control signals output terminals

    S1, S2, GND and +24V: system bus connection terminals

    A, PGND and B: RS485 communication interface connection terminals


    Product detail pictures:

    Combustible Gas Detection Controller Gas Alarm Controller AEC2303a – Action detail pictures

    Combustible Gas Detection Controller Gas Alarm Controller AEC2303a – Action detail pictures


    Related Product Guide:

    Gaining customer satisfaction is our company's aim forever. We will make great efforts to develop new and top-quality products, meet your special requirements and provide you with pre-sale, on-sale and after-sale services for Combustible Gas Detection Controller Gas Alarm Controller AEC2303a – Action , The product will supply to all over the world, such as: belarus, Salt Lake City, Singapore, Our stock have valued 8 million dollar , you can find the competitive parts within short delivery time. Our company is not only your partner in business, but also our company is your assistant in the coming corporation.
    Although we are a small company, we are also respected. Reliable quality, sincere service and good credit, we are honored to be able to work with you!
    5 Stars By Aurora from United Arab emirates - 2018.09.29 13:24
    The sales person is professional and responsible, warm and polite, we had a pleasant conversation and no language barriers on communication.
    5 Stars By Adam from Johannesburg - 2018.05.22 12:13
    Write your message here and send it to us