banenr

product

Combustible Gas Detection Controller Gas Alarm Controller AEC2303a – Action

Short Description:

  • logo1
  • logo2
  • logo3
  • logo4
  • logo5
  • logo6
  • logo7
  • logo8
  • logo9
  • logo10
  • logo11
  • logo12
  • logo13
  • logo14
  • ACTION gas detectors are OEM & ODM supported and true mature devices, long-tested in millions of projects domestic and overseas since 1998! Don't hesitant to leave your any inquiry here!


    Product Detail

    Product Tags

    Related Video

    Feedback (2)

    It adheres on the tenet "Honest, industrious, enterprising, innovative" to acquire new solutions regularly. It regards shoppers, success as its very own success. Let us establish prosperous future hand in hand for Co Detector Gas Leak, toxic gas detector, 220v Gas Detector Alarm, We are looking forward to forming successful business relationship with new clients in the near future!
    Combustible Gas Detection Controller Gas Alarm Controller AEC2303a – Action Detail:

    Technical Specifications

    Operating voltage  AC176V~AC264V (50Hz±1%)
    Power consumption  ≤10W (excluding supporting equipment)
    Environmental condition for operating  temperature-10℃~+50℃, relative humidity≤93%RH
    Signal transmission  four-bus system (S1, S2, +24V and GND)
    Signal transmission distance  1500m (2.5mm2)
    Types of gas detected  %LEL
    Capacity  total number of detectors and input modules≤4
    Adaptive equipment  gas detectors GT-AEC2331a, GT-AEC2232a, GT-AEC2232bX/A
    Input module  JB-MK-AEC2241 (d)
    Fan linkage boxes  JB-ZX-AEC2252F
    Solenoid valve linkage boxes JB-ZX-AEC2252B
    Output  two sets of relay contact signals, with the capacity of3A/DC24V or 1A/AC220V RS485Bus communication interface (standard MODBUS protocol)
    Alarm setting  low alarm and high alarm
    Alarming mode  audible-visual alarm
    Display mode  nixie tube
    Boundary dimensions(length ×width ×thickness)  320mm×240mm×90mm
    Mounting mode  wall-mounted
    Standby power supply  DC12V /1.3Ah ×2

    Major Features

    ● Bus signal transmission, strong system anti-interference capability, cost-efficient wiring, convenient and efficient installation;

    ● Real-time gas concentration (%LEL) monitoring interface or time display interface for user’s choice;

    ● One-button start for simple and convenient system commissioning;

    ● Freely setting the alarm values of the two alarming levels in the full-scale range;

    ● Automatic calibration, and automatic tracing of sensor ageing;

    ● Automatically monitoring failure; correctly showing the failure location and type;

    ● Two sets of programmable internal linkage output modules and two programmable emergency buttons to automatically or manually control external equipment;

    ● Strong memory: historical records of the latest 999 alarming records, 100 failure records and 100 startup/shutdown records, which will not be lost in case of power failure;

    ● RS485 bus communication (standard MODBUS protocol) interface to realize communication with the host control system and networking with the fire and gas network system, to improve system integration.

    Structure

    1. Side lock
    2. Cover
    3. Horn
    4. Bus connection terminal
    5. RS485 bus communication interface
    6. Relay connection terminal
    7. Bottom box
    8. Incoming hole
    9. Grounding terminal
    10. Power supply terminal
    11. Switch of main power supply
    12. Switch of standby power supply
    13. Switch power supply
    14. Standby power supply
    15. Control panel

    Panel Marks And Mounting Instructions


    ● Make 4 mounting holes (hole depth: ≥40mm) in a wall as per the requirements for bottom board mounting holes (hole symbols 1-4);

    ● Insert a plastic expansion bolt into each mounting hole;

    ● Fix the bottom board onto the wall, and fasten it onto the expansion bolts with 4 self-tapping screws (ST3.5×32);

    ● Hang the welding hanging parts on the back of the controller onto location A at the bottom board to complete mounting of the controller.

    Panel Marks And Mounting Instructions

    L,and N: AC220V power supply terminals

    NC (normally closed), COM (Common) and NO (normally open): (2 sets) output terminals for relay external control signals output terminals

    S1, S2, GND and +24V: system bus connection terminals

    A, PGND and B: RS485 communication interface connection terminals


    Product detail pictures:

    Combustible Gas Detection Controller Gas Alarm Controller AEC2303a – Action detail pictures

    Combustible Gas Detection Controller Gas Alarm Controller AEC2303a – Action detail pictures


    Related Product Guide:

    We always believe that one's character decides products' quality, the details decides products' high-quality ,together with the REALISTIC,EFFICIENT AND INNOVATIVE crew spirit for Combustible Gas Detection Controller Gas Alarm Controller AEC2303a – Action , The product will supply to all over the world, such as: Luxemburg, Malawi, Estonia, For anyone who is keen on any of our goods right after you view our product list, please really feel absolutely free to get in touch with us for inquiries. You are able to send us emails and contact us for consultation and we shall respond to you as soon as we can. If it's easy, you may locate out our address in our web-site and come to our business for far more information of our products by your self. We are always ready to construct extended and steady co-operation relations with any possible customers in the related fields.
    The product manager is a very hot and professional person, we have a pleasant conversation, and finally we reached a consensus agreement.
    5 Stars By Atalanta from Lithuania - 2017.01.28 18:53
    It is a very good, very rare business partners, looking forward to the next more perfect cooperation!
    5 Stars By Alice from Mecca - 2017.11.01 17:04
    Write your message here and send it to us