    Having a positive and progressive attitude to customer's fascination, our organization constantly improves our solution high-quality to fulfill the requirements of shoppers and further focuses on safety, reliability, environmental prerequisites, and innovation of 4 Gas Monitors, Gas Monitor, Lel Of Methane Gas, We take quality as the foundation of our success. Thus, we focus on the manufacture of the best quality products. A strict quality management system has been created to ensure the quality of the products.
    4 Gas Monitor Alarm Levels GT-AEC2338 Fixed Gas Detector – Action Detail:

    Technical Parameters

    Item

    Data

    Detected gases

    Combustible gases and steams, toxic and hazardous gases (see A01, A03 and B04~B29 in the list of detectable gases)

    Sampling mode

    Diffusive sampling

    Operating voltage

    DC24±6V

    Power consumption

    ≤3W (DC24V)

    Display

    LCD display

    Calibration

    By keys or a remote controller

    Signal transmission distance

    ≤1500m (2.5 mm2)

    Protection grade

    IP66

    Explosion proof grade

    ExdⅡCT6Gb

    Signal transmission

    Three-wire (4~20)mA standard signals [support HART] and 3 sets of relay signals

    Outlet hole connecting thread

    NPT3/4"(female)

    Material

    Cast aluminum

    Dimension

    Length × width × height: 228mm×177mm×87mm

    Weight

    1.9 kg

    Major Features

    Highly-integrated functional module design

    The integrated functional module is made up of two parts, i.e. detector module and sensor module. Anti-misplug standard digital interface is used between the two modules, good for on-site hot plug replacement;

    Alarm concentration can be set freely within the full range

    Low alarm concentration and high alarm concentration can be set freely within the full range. As keys are used for calibration, the calibrated value can be set according to calibrated gas concentration. Concentration is displayed through LCD on a real-time basis. On-site calibration can also be perfomed with an IR remote controller. At the time of calibration, it is unnecessary to open the cover. The operation is easy and convenient;

    Military-grade LCD display

    LCD real-time concentration display, clearly indicating equipment working conditions under highlight and in distance;

    Multiple communication modes are available

    Such product types as three-wire (4-20mA), two-wire (4-20mA), and 4-20mA with HART are available for selection;

    Flexible combination and multiple output modes

    Multiple detector modules and multiple types of sensor modules can be combined flexibly to form detectors with special output functions and applicable to different targets to meet customers’ customized demands;

    Replace a sensor as easy as replacing a bulb

    Sensor modules for different gases and ranges can be replaced freely. No calibration is required after replacement. That is, the detector can read ex-factory calibrated data and work immediately. In this way, the product has a longer service life. Meanwhile, detection calibration can be done easily at different sites, avoiding complicated dismantling process and difficult on-site calibration and reducing later maintenance cost.

    Model Selection

    Model

    Signal output

    Sensor equipped

    Adaptive control system

    AEC2338

    Three-wire (4~20)mA standard signal (supporting HART) and three sets of relay signals

    Two-wire (4~20)mA standard signal (supporting HART)

    Catalytic combustion, semiconductor, electrochemical, IR & PID

    ACTION gas alarm controllers:

    AEC2392a, AEC2392b, AEC2393a , AEC2393b2a-BS, AEC2393b2a-BM

    Detector Structure

    Boundary Dimension

    Material cast aluminum; Dimension: Length× width× height: 228mm×177mm×87mm Weight: 1.9 kg

    Mounting Mode

    Vertical pipe-mounted / Horizontal pipe-mounted / Wall-mounted / Ceiling-mounted


    Product detail pictures:

    4 Gas Monitor Alarm Levels GT-AEC2338 Fixed Gas Detector – Action detail pictures

    4 Gas Monitor Alarm Levels GT-AEC2338 Fixed Gas Detector – Action detail pictures

    4 Gas Monitor Alarm Levels GT-AEC2338 Fixed Gas Detector – Action detail pictures


    Related Product Guide:

    We have our own sales team, design team, technical team, QC team and package team. We have strict quality control procedures for each process. Also, all of our workers are experienced in printing field for 4 Gas Monitor Alarm Levels GT-AEC2338 Fixed Gas Detector – Action , The product will supply to all over the world, such as: UK, Canada, Oslo, As a well educated, innovative and energetic staff,we are responsible for all elements of the research, design, manufacturing, sales and distribution. With studying and developing new techniques,we are not only following but also leading the fashion industry. We listen attentively to the feedback from our customers and provide instant communication. You will instantly feel our expertise and attentive service.
    This enterprise in the industry is strong and competitive, advancing with the times and develop sustainable, we are very pleased to have a opportunity to cooperate!
    5 Stars By Doris from Belize - 2017.11.11 11:41
    Company director has very rich management experience and strict attitude, sales staff are warm and cheerful, technical staff are professional and responsible,so we have no worry about product,a nice manufacturer.
    5 Stars By Esther from Adelaide - 2017.01.11 17:15
    Write your message here and send it to us