Gas Control Panel Gas Alarm Controller AEC2392b – Action Detail:

Technical Specifications

Item  

Data

Operating voltage

AC220V±15% (50Hz±1%)

Capacity

1~4 points

Types of gas detected

%LEL, 10-6, %VOL and switching value signals

Range

Combustible gas: max. 100 (%LEL)

Toxic gas: max. 9,999 (10-6)

Oxygen: max. 100 (%VOL)

Power consumption

≤10W (excluding supporting equipment)

Load capacity

the max. output current of a single service circuit 24V ≤300mA

Environmental condition for operating

Temperature: 0℃~40℃; relative humidity≤93%RH

Alarming mode

audible-visual alarm

Value indication error

±5%FS

Alarming error

±15% of the alarming concentration

Display mode

nixie tube

Signal transmission

4~20mA standard signal (three-wire system)

Signal transmission distance

≤1000m (1.5mm2)

Output

five sets of relay contact signals, with the capacity of 10A/DC24V or 10A/AC220V

RS485 bus interface (standard MODBUS protocol)

Boundary dimensions

Length × width × thickness: 365mm×220mm×97mm

Gross weight

about 6kg

Standby power supply

12VDC/2Ah×2

Mounting mode

wall-mounted

Adaptive detectors

Gas detectors: GT-AEC2232bX,

GQ-AEC2232bX, GT-AEC2232aT, AEC2338, GQ-AEC2232bX -P, AEC2338-D

Fan linkage box: JB-ZX-AEC2252F

Solenoid valve linkage box: JB-ZX-AEC2252B

Major Features

● Meet the need of connecting standard 4-20mA current signal detectors at 1-4 point locations;

● With a small size, the product can be wall-mounted easily. Two sets or more can be installed side by side to meet customer’s demands for more point locations (wall mounting of 8, 12, 16 or more point locations can be realized through gapless combination);

● Monitoring and display of real-time concentration (%LEL, 10-6, %VOL) as well as switching value signals of combustible gas, toxic gas and oxygen (default is combustible gas detector. No setting is required. It is available for use after being installed and electrified);

● Each circuit links one switching value output. If necessary, linking programming setting can be realized through the menu. Each product has one RS485 digital interface to communicate with the host computer;

● The visual range is farther and the visual angle is wider. Concentration contains 4 effective digits. Display with an accuracy of 9999~0.001 is available;

● Save the latest 999 alarming records and 999 failure records.

Structure

1. Side lock
2. Cover
3. Casing ground
4. User connection terminal
5. User connection terminal
6. Incoming hole
7. Bottom box
8. Power supply terminal
9. Switch of main power supply
10. Switch of standby power supply
11. Switch power supply
12. Standby battery
13. Battery holder
14. Horn
15. Control panel
16. Anti-collision mat

Panel Marks And Mounting Instructions


● Make 4 or 6 mounting holes (hole depth: ≥40mm) in a wall according to the requirements for the size among mounting holes (hole symbols 1 – 6) for mounting the hanging plate;

● Insert a plastic expansion bolt into each mounting hole;

● Fix the hanging plate onto the wall and fasten it onto the expansion bolts with 4 or 6 self-tapping screws (ST4.2×25);

● Hang the hanging parts at the bottom of the controller onto location A at the bottom board to complete mounting of the controller.

System Configuration

AEC2392b has 4 sets of branch-line connection terminals that can be connected to the branch-line communication equipment manufactured by the company such as detectors AEC2232b, AEC2232bX, GQ-AEC2232b, GQ-AEC2232bX and AEC2232aT, or other transmitters with 4~20mA signal outputs to monitor and control the gas concentration at site. Meanwhile, remote logical control over external equipment (in-situ audible-visual, solenoid valves and fans, etc.) can be realized through 5 sets of built-in programmable modules. In addition, remote communication with the monitor system can be realized through the RS485 communication interface.


Product detail pictures:

Gas Control Panel Gas Alarm Controller AEC2392b – Action detail pictures

Gas Control Panel Gas Alarm Controller AEC2392b – Action detail pictures


Related Product Guide:

Our company promises all users of the first-class products and the most satisfying post-sale service. We warmly welcome our regular and new customers to join us for Gas Control Panel Gas Alarm Controller AEC2392b – Action , The product will supply to all over the world, such as: Swiss, Iraq, Swedish, Corporate goal: Customers' satisfaction is our goal, and sincerely hope to establish long-terms stable cooperative relations with customers to jointly develop the market. Building brilliant tomorrow together!Our company regards "reasonable prices, efficient production time and good after-sales service" as our tenet. We hope to cooperate with more customers for mutual development and benefits. We welcome potential buyers to contact us.
The company can think what our think, the urgency of urgency to act in the interests of our position, can be said this is a responsible company, we had a happy cooperation!
5 Stars By Harriet from Hungary - 2017.06.19 13:51
Products and services are very good, our leader is very satisfied with this procurement, it is better than we expected,
5 Stars By Antonio from Turkmenistan - 2018.12.28 15:18
Write your message here and send it to us